EBOO Equipment Support & Documentation

Written documentation and self-guided video material are included with every device. Onsite or live virtual orientation can be arranged on request and is quoted separately. Contact info@eboofilters.com to request documentation or orientation.

What's included with every EBOO O3 Research Device

  • Operator manual plus setup, calibration, and parameter-control references.
  • Safety-procedure protocols and troubleshooting guidance.
  • Consumable installation and replacement instructions (PES H200 filter, tubing, line sets).
  • Self-guided video documentation. Onsite or live virtual orientation can be arranged on request and is quoted separately.

EBOO O3 five-stage research process flow

  1. Fluid medium introduction — medium enters the closed-loop circuit.
  2. Gas infusion — controlled ozone/oxygen infusion.
  3. Particulate filtration — through the PES H200 high-flux filter.
  4. UV light exposure — controlled-spectrum UVBI chamber stage.
  5. Medium return — processed medium exits the circuit.

Operating specifications documented

  • Operating modes: EBOO mode 3–5 gamma (3–5 µg/mL); EBO2 mode 20–30 gamma (20–30 µg/mL).
  • Filter membrane: PES H200 high-flux polyethersulfone (dialyzer-style). Browse EBOO filters.
  • Connectors: standardized luer-lock line sets and silicone tubing. Browse EBOO lines & tubing.
  • Consumables: sterile, single-use per research cycle. See EBOO supply kits.
  • Equipment: the 2026 EBOO O3 Research Device integrates a peristaltic pump, UVBI chamber, and safety interlocks.

Research Use Only. Not a medical device and not FDA-cleared or approved for clinical use. Documentation and orientation support qualified researchers operating equipment in controlled laboratory settings.

What the included documentation covers

Every EBOO O3 Research Device 2026 ships with a written documentation set plus remote technical support. The documentation is reference material for qualified laboratory personnel; it is not a live or in-person training course.

  • Device orientation and controls — enclosure layout, touchscreen navigation, parameter entry, and the meaning of each on-screen state and alarm.
  • Priming and line-set installation — unpacking a single-use kit, seating the line set, connector orientation, priming the circuit, and the pre-run leak and air check.
  • Ozone concentration and flow settings — setting concentration across the 1–35 gamma range (EBOO mode 3–5 gamma, EBO2 mode 20–30 gamma), circuit flow of 2.5–5 L/hr, and pump speed 1–99.
  • UV chamber and cuvette handling — seating a cuvette line segment in the 5-lamp chamber, inspecting the housing window, and lamp-hour tracking.
  • Ozone destruct unit — installation, carbon-catalyst service interval, and exhaust routing.
  • Cleaning, maintenance and lamp-hour logs — surface cleaning, pump-section inspection, scheduled maintenance items, and the log templates used to record them.
  • Record-keeping — per-run parameter records, consumable lot capture, and maintenance history tied to the device serial number.

Replacement procedures for filters, tubing, and line sets are also documented step by step in our replacement guide. Research and laboratory use only. Not a medical device and not FDA-cleared for clinical, diagnostic, or therapeutic use.

Frequently asked questions

What documentation is included with the EBOO O3 Research Device?

Every EBOO O3 Research Device 2026 ships with an operator manual, a setup and calibration reference, safety-procedure protocols, consumable installation instructions, and troubleshooting guidance for controlled laboratory research use.

How does the EBOO O3 Research Device process flow work?

The device runs a closed-loop, five-stage research process: (1) fluid medium introduction, (2) controlled ozone/oxygen gas infusion, (3) particulate filtration through the PES H200 filter, (4) UV light exposure in the UVBI chamber, and (5) processed medium return.

Do you provide onsite or virtual orientation for the EBOO O3?

Yes, on request. Onsite or live virtual orientation is arranged for qualified research teams and quoted separately; written and video documentation is included with every device.

What operating parameters does EBOO device documentation cover?

Documentation covers EBOO mode at 3–5 gamma (3–5 µg/mL) and EBO2 mode at 20–30 gamma (20–30 µg/mL), peristaltic pump flow control, UVBI chamber operation, PES H200 filter installation, and luer-lock line-set connection.

How are EBOO consumables installed and replaced?

EBOO filters, tubing, and line sets are sterile, single-use, and connect tool-free with luer-lock fittings. Install a fresh PES H200 filter, tubing, and line set each research cycle; the EBOO supply kits page lists kit contents and the step-by-step replacement procedure.

Is orientation required to purchase the EBOO O3 Research Device?

No. Technical documentation and support resources are included with every device; onsite or virtual orientation is optional, arranged on request and quoted separately.

Is the EBOO O3 Research Device FDA-cleared or a medical device?

No. The EBOO O3 Research Device and all EBOO consumables are supplied for controlled laboratory and research use only. Not a medical device and not FDA-cleared or approved for clinical use.

Is training included with the EBOO O3 Research Device?

Technical documentation is included with every device: an operator manual, setup and calibration references, safety protocols, consumable replacement procedures, and troubleshooting guidance. We supply documentation and remote technical support rather than a scheduled training course.

Who can access the technical documentation?

Documentation is provided to qualified researchers and laboratory personnel at the purchasing institution. Email info@eboofilters.com from an institutional address with your device serial number and we will send the current documentation set.

Do you provide replacement-procedure guides?

Yes. Written procedures cover PES H200 filter installation, line-set and tubing replacement, cuvette handling for the UV chamber, priming, and ozone destruct unit servicing, including the pre-run checks that precede each research cycle.

How do I get technical support?

Email info@eboofilters.com or call 505-597-0834 with your device serial number and a description of the parameter, consumable, or maintenance question. Support covers device operation, documentation, and compatibility of filters, lines, and accessories.